Welcome
Guest
, you are in:
<root>
•
Login
FLSmidth QCX wiki
Main Page
Random Page
Create a new Page
All Pages
Categories
Navigation Paths
Administration
File Management
Word Import
Create Account
Search the wiki
Back
Add Online to BLX
Modified on 2019/03/28 07:42
by
RSk
Categorized as
How to
,
QCX BlendExpert Mill V8
{| |- | BLX V8 Adding an '''Online Analyser''' |- | '''Date:''' | 18/01/2019 |- | '''Author:''' | Mette Katrine Runge |- | '''Who can use this'''': | FLSA Engineers with some XML copy/paste, search/replace capabilities |- | '''Notes'''': | Only supports addition of Online Analyser to an already installed BLX. You need the original BLX engineering excel spreadsheet to build new solutions including the Online analyser Time estimate 1 hour. If this guide is followed |- | '''Support files'''': | Can be found on the BLX Super user site. The zip files contains an example of the solutions files ready for import into QCX after finished editing. Also is a recording of Torsten showing the procedures |} ==This info can also be found on the BLX Super User site== ==Step by Step== * Make a backup of configuration and runtime databases… in the unlike event of something goes bad * Create new BLX engineering file based on the original file and including the new Online Analyser and the preferred configuration. * Use BLX Builder to create new solution files * The following files needs to edited (see also link above to example of files): ** Specific Solution: *** Fls.Core.Config.Solution.xml *** Fls.Core.Ref.xml *** Fls.QcxBlx.Mill.Config.xml ** HMI Solution *** Fls.Core.Config.Solution *** Fls.Core.Hmi *** Folder: Fls.Core.Hmi * Delete all EXCEPT the three files defining the online. * In each file delete everything not related to the Online Sampler as described in the following table: <style type="text/css"><![CDATA[TD.Index1 { border-top-style: inset; border-top-width: 1px; border-top-color: black; border-bottom-style: inset; border-bottom-width: 1px; border-bottom-color: black; border-left-style: inset; border-left-width: 1px; border-left-color: black; border-right-style: inset; border-right-width: 1px; border-right-color: black; }]]></style> {| |- | class="Index1" | '''File''' | class="Index1" | '''Delete''' |- | class="Index1" | Specific solution: Fls.Core.Config.Solution.xxml | class="Index1" | Noting to delete here Make sure naming is correct on Designation solution and sourceName. Check QCX configuration in: Core.Config.Solution |- | class="Index1" | Specific solution: Fls.Core.Ref.xml | class="Index1" | Remember to keep the original roote down to the info on the Online Analyser – see example Else delete all not related to the online sampler. |- | class="Index1" | Specific solution: Fls.QCX.Blx.Config.xml | class="Index1" | Delete all sections '''NOT''' related to the Online Analyser. Remember to delete the three lines called: successorSubsection related to the online sampler. Can be found towards the end of the file. Do a search. |- | class="Index1" | HMI Solution: Fls.Core.Hmi | class="Index1" | Under Mimics: delete all files '''NOT''' related to the Online Analyser |- | class="Index1" | HMI solution: Fls.Core.Hmi.xml | class="Index1" | Delete everyting '''NOT''' related to the online analyser |} ==Transfer the files to the system== Import the solutions folders to QCX * Ensure the files are in the original solutions – have right solution names! * In Config – Config – Blx – Plantsection add the online to the list of subsections by adding a new line and selection the Online. * In Config – Config – Blx – Subsection change successorSubsections to right order for example: Merger delay 1 online mill lab ….. * Edit the HMI and add the online mimics in the Matric.
Meta Keywords:
Meta Description:
Change Comment:
FLSmidth