BLX Engineering Tool: SamplerOxide

RSS
Modified on 2019/10/01 13:57 by Vojtech Beil Categorized as QCX BlendExpert Mill V8

SamplerOxides table

Table SamplerOxide
SamplerOxideStandardDeviationSelectedForEstimation
  % 
    

  • Sampler - Reference to existing sampler
  • Oxide - Oxide
  • StandardDeviation - unit: %
  • SelectedForEstimation - true/false



In the table for the sampler oxide are listed the standard deviation from the labsampler. These data are supplied by the site.

If the site dont have the data a standard of 0.1 can be entered and when on site for commissioning the right values can be entered.

The data are listed in BLX as the samplers standard deviation / noise and should be as correct as possible. If the numbers seems to large then get the site to calculate new values:

Take a batch of Raw meal from the sampler and prepare 12 samples for analysis. A standard deviation of this is then calculated.








 