Sum constraints above 100 (100<sum of Oxides + LOI)
Modified on 2017/09/06 14:16
by
MKR
Categorized as
QCX BlendExpert Mill V8
===This warning means that the sum of the oxides including the LOI corrections are about 100%.=== BLX is normally per default set up with the following LOI: CaO: 0.786 and MgO: 1.089. This LOI for CaO assumes that all Ca is bound in CaCO3. This is often not the case and it is therefore OK to lower the value if needed. [image:{UP(Sum-constraints-above-100-100-sum-of-Oxides-LOI)}Sum Constraint_1.png|medium|left|Image #1] This can be corrected by lowering the LOI for CaO to: for instance: 0.686 so the factor multiplied is: 1.686 instead of 1.786. See image 1. The factor can be lowered in: * '''System --> Configuration --> Configuration --> BLX --> Mill --> Dataitem''' Remember to select the right solution to be able to change the values. [image:{UP(Sum-constraints-above-100-100-sum-of-Oxides-LOI)}Sum Constraint_2.png|medium|left|Image #2]
Meta Keywords:
Meta Description:
Change Comment:
FLSmidth