Welcome Guest, you are in: Login

FLSmidth QCX wiki

RSSRSS





Search the wiki
 

Sum constraints above 100 (100<sum of Oxides + LOI)

RSS
Modified on 2017/09/06 14:16 by MKR Categorized as QCX BlendExpert Mill V8

This warning means that the sum of the oxides including the LOI corrections are about 100%.

BLX is normally per default set up with the following LOI: CaO: 0.786 and MgO: 1.089.

This LOI for CaO assumes that all Ca is bound in CaCO3. This is often not the case and it is therefore OK to lower the value if needed.

Image #1











This can be corrected by lowering the LOI for CaO to: for instance: 0.686 so the factor multiplied is: 1.686 instead of 1.786. See image 1.

The factor can be lowered in:
  • System --> Configuration --> Configuration --> BLX --> Mill --> Dataitem

Remember to select the right solution to be able to change the values.

Image #2







































  Name Size
- Sum Constraint_1.png 28.15 KB
- Sum Constraint_2.png 119.42 KB